How high chimney above roof line uk.
Flues need to be 600mm higher than the highest part of the roof within 3 metres.
The chimney should extend at least 3 feet above the roof surface it penetrates and 2 feet higher than any roofline or other obstacle within a horizontal distance of 10 feet.
The chimney must extend at least 3 above the highest point where it passes through a roof.
This is a bit of an odd measurement and chimney clearance case because the chimney side is actually about 8 away from the roof edge.
The height of the chimney above the roof surface measured at the up slope side of the chimney from the roof surface to the chimney top should be at least three feet the green line in our photo.
The 10 foot rule explains the clearance you need.
These rules helps ensure draft is not spoiled by wind induced turbulence.
Degrees the height of flue or chimney stack will need to be at least 1800mm above the roof when not close to the ridge.
Two things determine chimney draft.
They intend to make sure that the chimney draws properly and that a fire hazard does not occur.
If the top of the chimney is within 600mm 60cm of the ridge it should finish 60cm higher than the ridge.
Look at the top of your chimney where the smoke comes out.
We also have the 2 3m rule.
Homes built on varying terrain have their own set of chimney and flue regulations.
If the pitch of the roof is 38 degrees or greater the termination point of the flue or chimney will need to be 2300mm horizontally from the roof line and roofing material.
Anon the chimney outlet needs to not only be proper height above the roof surface but proper distance from any opening that could take flue exhaust.
Flues that are more than 3 metres away from the highest part of the roof need to be 1000mm above the flue penetration.
And at least 2 higher than any portion of a building within 10.
Chimney height may need to be increased by 2 3 per 1000 feet of elevation although added height generally equates to stronger draft there is a point where the system can become too long and over drafting might occur.
Imagine an imaginary horizontal line extending 2 3m in all.
Both above the flat roof and 2 feet above the point at which a horizontal line from the chimney would touch the highest portion of the nearest roof.
If the pipe is farther than 10 feet from the roof.
Taller chimneys make more draft but chimneys exposed to outside cold don t.